Improving the Seismic Response of Tall Buildings: From Diagrid to Megastructures and Mega-Subcontrol Systems

2022

Background: Diagrid structures, widely used for the tall buildings of the third millennium, are characterized by a very effective behaviour in the elastic field due to the grid triangulation. In particular, under horizontal actions, axial forces and deformations mainly arise in the structural members of the diagrid, thus resulting in the reduction of the shear lag effect and racking deformations. The response to incremental horizontal actions beyond the plastic threshold, however, shows a poor plastic redistribution capacity, with consequent low values of global ductility, in spite of a significant design overstrength. Objective: In this paper, it is proposed to exploit the high elastic ef…

Diagrid structures Megastructures Mega-sub-structures Seismic response Vibration control Non-conventional tuned mass damper.Building and Construction
researchProduct

Intermediate Isolation System for the seismic retrofit of existing masonry buildings

2022

This paper deals with the potentials of Intermediate Isolation Systems (IIS) for retrofitting masonry buildings by means of a vertical extension, isolated at its base, and realized on the rooftop of the existing structure. By carefully defining the dynamic properties of the superstructure and isolation system, in previous papers the authors have demonstrated that this passive technique is able to reduce a priori the seismic demand on the existing building. For this reason, the non-linear behavior has been only assumed for the isolation system, with the masonry structure in the elastic field. This result has been validated by carrying out spectrum-compatible time history analyses on the 3D F…

masonry buildingsInter-story isolation systemseismic isolationnon-conventional tuned mass damperseismic retrofit
researchProduct